Editing FCD

Unified Glossary

Basics of using a typical web page

Using Online Help

This page allows you to edit the details of the selected FCD. FCDs that are in “Fresh” status can be modified. Tell me more.

The “Edit Fleet Campaign Directive” page appears.

The system displays the following field:

Date Format

The format in which the date fields must be entered in this page. This format is displayed from the "User Preferences" business component based on the login user ID. In case the format is not defined, the system displays the date format from the “Enterprise Modeling” business component by default.

The system displays the following in the “FCD Details” group box:

FCD #

The FCD for which the details are to be modified.

Status

The status of the FCD, which could be “Fresh”.

FCD Category

Use the drop-down list box to modify the category to which the FCD belongs. The system lists all the active quick codes that are of type “FCD Category” as defined in the “Create Quick Codes” activity.

If you do not wish to specify the category, you can leave this field blank.

User Status

Use the drop-down list box to modify the user-defined status of the FCD. The system lists all the active quick codes that are of type “FCD User Status” as defined in the “Create Quick Codes” activity.

If you do not wish to specify the user status, you can leave this field blank.

Subject

The textual description of the FCD (Alphanumeric, 255). Mandatory.

Zoom facility available.

ATA #

The  ATA chapter on which the FCD must be executed (Alphanumeric, 16). Mandatory. The ATA chapter should be in “Active” status in the “Aircraft” business component.

Help facility available.

Applicability

Use the drop-down list box to specify whether the FCD is applicable for “Aircraft”, “Engine” or “Component”.

Note: You can modify the FCD applicability only when the effectivity details are not specified.

Priority

Use the drop-down list box to modify the priority for the FCD. This indicates the level of urgency. For example, in a set of priority numbers 1, 2, 3 and 4, the priority number “1” will be treated as of highest priority. The system lists all the priority descriptions defined in the “Create Priority Numbers” activity of the “Common Masters” business component.

The system displays the following field:

Authorization Status

The authorization status of the FCD, which could be “Pending“ or “Authorization Not Required”.

Back Ground

The textual description of the background information such as the prerequisites for the current change (Alphanumeric, 2000).

Zoom facility available.

Reason

The textual information detailing the reason for which the FCD has been created (Alphanumeric, 255).

Zoom facility available.

Work Center #

Use the drop-down list box to modify the work center where the FCD has to be performed. The system lists all the work centers that have been defined in the “Create Work Center” activity of the “Work Center” business component.

The system displays the following field on clicking the “Create FCD” pushbutton:

Work Center Description

The textual description of the work center.

Zoom facility available.

Est. Elapsed Time

The total time estimated for completing the FCD (Decimal). Mandatory. Ensure that the number entered in this field is positive.

Use the drop-down list box provided alongside, to specify the unit of measurement for the time allotted for the FCD. The system displays the options “Minutes”, “Hours” and “Days”, and sets the field to “Hours” by default.

Est. Man Hrs.

The total man-hours estimated for “Skill” type resources to execute the FCD (Decimal). Mandatory. Ensure that the number entered in this field is positive.

On-Wing

Check this box to indicate that the change can be performed when the part is fitted to the aircraft.

Follow - Up Action Reqd.

Check this box to indicate the follow-up action is required after performing the FCD.

The system displays the following fields in the “Reference Document Details” group box:

MCM #

The number identifying the Modification Committee Meeting (MCM) that processed the FCD.

MCM Date

The date on which the MCM was convened.

MCR #

The number identifying the Maintenance Change Request (MCR) for which the FCD was created.

Revision #

The revision number of the MCR.

Applicability Group

The applicability group of the MCR.

Source Doc Type

The type of the modification document or the source document.

File Name

The name of the file that you wish to attach to the FCD (Alphanumeric, 50). This can be the document that contains information regarding FCD modification or any other document with respect to FCD.

Help facility available.

Zoom facility available.

 Comments

Any comment pertaining to the cancellation of fleet campaign directive (Alphanumeric, 255)

Zoom facility available

The system displays the following field:

Link Info

Indicates whether aircraft effectivity details, part effectivity details, part requirement, resource requirement, reference details, or periodicity details are entered for the FCD. The system displays one or more of the following:

 

  • AcEff - if aircraft effectivity details are available

  • PartEff – if part effectivity details are available

  • Tsk – if task details have been entered

  • P – if part requirements are specified

  • R - if resource requirements are specified

  • Ref – if reference details are available

  • Prd – if periodicity details are available

If more than one of the above details are identified for the FCD, the variables will be separated by “\”.

 

The system displays the following field in the “Record Statistics” group box:

Created By

The login ID of the user who created the FCD.

Created Date

The date on which the FCD was created.

Last Modified By

The login ID of the user who last modified the FCD details.

Last Modified Date

The date on which the last modification was done.

The system updates the status of the FCD to “Fresh”.

Note: This action is workflow-enabled. Notification messages can be sent as per the settings you have defined in the "Workflow Management" business component.

The system sets the FCD to “Cancelled” status.

To proceed, carry out the following:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Editing FCD – An overview

This page allows you to edit the details of the selected FCD. FCDs that are in “Fresh” status can be modified. You can edit the category, user status, description and the ATA chapter on which the engineering change has to be performed.

You can modify whether the FCD is applicable for the aircraft, component or engine, priority, background details and reasons. The execution details of the FCD such as the work center, in which the FCD has to be performed, estimated time and man-hours required for the execution of the FCD, can also be modified.

    You can also indicate whether,

You can cancel the FCD in this page. You can enter comments while canceling FCD.

The system performs the following, when the details are modified:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What you can do in this page

Edit FCD applicability

Modify FCD execution details

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edit FCD applicability

You can edit the applicability of FCD, ie. Whether it is applicable for aircraft, engine or component only when the effectivity details have not been already specified for the FCD.

In the “FCD Details” group box,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modify FCD execution details

You can specify the following details based on which FCD execution will take place: