Recording rules in the Define Rules popup
Click
the
icon in the Define Rules column of the Rule Details multiline.
The Define Rules popup appears.
The popup window displays the following:
Rule ID |
The unique identifier for the rule. |
Rule Description |
The description of the rule. |
Alert Rules For |
The component reliability analysis for which you want to define rule, such as NFF or LTR. |
Select AND or OR button.
Select the check box to add Not True condition to the expression that you will add below.
Select
the icon to add
expression
First drop-down list |
Use the drop-down list box to select the first variable in the rule expression. The drop-down list box displays options based on the value selected in the Alert Rules For field in the Manage Reliability Alert Definition page. § This drop-down list box displays: o “Avg. Time Since Attachment” and “Consecutive U/S Removals” only if the parameter 'Time Since Attachment based evaluation for LTR” is set as ‘Required’. o Further, both Avg. Time Since Attachment and Consecutive U/s Removals are mutually inclusive and must be defined together in a rule. § The system derives values for: o Avg. Time Since Attachment from the Re-Initialize-Update Parameter Values activity o Consecutive U/S Removals from the Manage Component Removal Info. activity § If 'Alert Rules For' is 'NFF' , the drop-down list box also displays: o NFF :: 2 Month o 2. NFF :: 12 Months o 3. NFF Rate :: 2 Months |
Second drop-down list |
Use the drop-down list box to select arithmetic sign to be included between expressions. The drop-down list box displays: § Greater Than § Greater Than or Equal to § Lesser Than § Lesser Than or Equal to § Equal to |
Third drop-down list box |
Use the drop-down list box to select the second variable in the rule expression. The drop-down list box displays options based on the value selected in the Alert Rules For field in the Manage Reliability Alert Definition page.
|
Select
the icon
to delete the expression
Select the Save pushbutton to save the rule definition.
The saved rule will be displayed in the Defined Rule Description field in the Rule Details multiline of Manage Fleet Alert Definition page.
An example of building rule
LHS <<Conditional Operator>> :: RHS <<Rule Operator>> LHS <<<<Conditional Operator>> :: RHS etc.,
The Conditional operator displays in RED color & The Rule operator in displays in GREEN color.
URR:: 3 Months GREATER THAN OR EQUAL TO Alert Level AND U/s Removals :: 12 Months GREATER THAN OR EQUAL TO 3
U/s Removals:: 1 Months GREATER THAN OR EQUAL TO 2 AND Parameter = FH AND Time Since Attachment LESS THAN OR EQUAL TO 100
An example for LTR evaluation rule
LTR = “Consecutive removals = 2 AND Avg. Time Since Attachment <= 100”
Current Date: 5-May-20; Last 3 removals of component P1 S1:
1. 15-May-2020 with TSA as on date as 90 FH
2. 30-Apr-2020 with TSA as on date as 85 FH
3. 17-Apr-2020 with TSA as on date as 110 FH
Applying LTR rule, TSA between removal instances (i) & (ii) will be 87.5 FH which is <= 100. Therefore, component P1 S1 will be flagged as LTR.