This page allows you to edit the details of the selected FCD. FCDs that are in “Fresh” status can be modified. Tell me more.
Click the hyperlinked FCD number in the "Select FCD" page.
The “Edit Fleet Campaign Directive” page appears.
The system displays the following field:
Date Format |
The format in which the date fields must be entered in this page. This format is displayed from the "User Preferences" business component based on the login user ID. In case the format is not defined, the system displays the date format from the “Enterprise Modeling” business component by default. |
The system displays the following in the “FCD Details” group box: |
|
FCD # |
The FCD for which the details are to be modified. |
Status |
The status of the FCD, which could be “Fresh”. |
Enter the following fields:
FCD Category |
Use the drop-down list box to modify the category to which the FCD belongs. The system lists all the active quick codes that are of type “FCD Category” as defined in the “Create Quick Codes” activity. If you do not wish to specify the category, you can leave this field blank. |
User Status |
Use the drop-down list box to modify the user-defined status of the FCD. The system lists all the active quick codes that are of type “FCD User Status” as defined in the “Create Quick Codes” activity. If you do not wish to specify the user status, you can leave this field blank. |
Subject |
The textual description of the FCD (Alphanumeric, 255). Mandatory. |
ATA # |
The ATA chapter on which the FCD must be executed (Alphanumeric, 16). Mandatory. The ATA chapter should be in “Active” status in the “Aircraft” business component. Help facility available. |
Enter the following field in the “Other Details” group box:
Applicability |
Use the drop-down list box to specify whether the FCD is applicable for “Aircraft”, “Engine” or “Component”. |
Note: You can modify the FCD applicability only when the effectivity details are not specified.
Priority |
Use the drop-down list box to modify the priority for the FCD. This indicates the level of urgency. For example, in a set of priority numbers 1, 2, 3 and 4, the priority number “1” will be treated as of highest priority. The system lists all the priority descriptions defined in the “Create Priority Numbers” activity of the “Common Masters” business component. |
The system displays the following field:
Authorization Status |
The authorization status of the FCD, which could be “Pending“ or “Authorization Not Required”. |
Enter the following fields:
Back Ground |
The textual description of the background information such as the prerequisites for the current change (Alphanumeric, 2000). |
Reason |
The textual information detailing the reason for which the FCD has been created (Alphanumeric, 255). |
Enter the following field in the “FCD Execution Details” group box:
Work Center # |
Use the drop-down list box to modify the work center where the FCD has to be performed. The system lists all the work centers that have been defined in the “Create Work Center” activity of the “Work Center” business component. |
The system displays the following field on clicking the “Create FCD” pushbutton:
Work Center Description |
The textual description of the work center. |
Enter the following fields:
Est. Elapsed Time |
The total time estimated for completing the FCD (Decimal). Mandatory. Ensure that the number entered in this field is positive. Use the drop-down list box provided alongside, to specify the unit of measurement for the time allotted for the FCD. The system displays the options “Minutes”, “Hours” and “Days”, and sets the field to “Hours” by default. |
Est. Man Hrs. |
The total man-hours estimated for “Skill” type resources to execute the FCD (Decimal). Mandatory. Ensure that the number entered in this field is positive. |
On-Wing |
Check this box to indicate that the change can be performed when the part is fitted to the aircraft. |
Follow - Up Action Reqd. |
Check this box to indicate the follow-up action is required after performing the FCD. |
The system displays the following fields in the “Reference Document Details” group box:
MCM # |
The number identifying the Modification Committee Meeting (MCM) that processed the FCD. |
MCM Date |
The date on which the MCM was convened. |
MCR # |
The number identifying the Maintenance Change Request (MCR) for which the FCD was created. |
Revision # |
The revision number of the MCR. |
Applicability Group |
The applicability group of the MCR. |
Source Doc Type |
The type of the modification document or the source document. |
Enter the following field in the "Document Attachment Details" group box:
File Name |
The name of the file that you wish to attach to the FCD (Alphanumeric, 50). This can be the document that contains information regarding FCD modification or any other document with respect to FCD. Help facility available. |
Select the “View File” link alongside to view the file details.
Enter the following field in the “Cancellation Comments” group box::
Comments |
Any comment pertaining to the cancellation of fleet campaign directive (Alphanumeric, 255) |
The system displays the following field:
Link Info |
Indicates whether aircraft effectivity details, part effectivity details, part requirement, resource requirement, reference details, or periodicity details are entered for the FCD. The system displays one or more of the following: |
|
If more than one of the above details are identified for the FCD, the variables will be separated by “\”. |
The system displays the following field in the “Record Statistics” group box:
Created By |
The login ID of the user who created the FCD. |
Created Date |
The date on which the FCD was created. |
Last Modified By |
The login ID of the user who last modified the FCD details. |
Last Modified Date |
The date on which the last modification was done. |
Click the “Edit FCD” pushbutton, to update the modified FCD details.
The system updates the status of the FCD to “Fresh”.
Note: This action is workflow-enabled. Notification messages can be sent as per the settings you have defined in the "Workflow Management" business component.
Click the “Cancel FCD” pushbutton, to cancel the FCD.
The system sets the FCD to “Cancelled” status.
To proceed, carry out the following:
Select the “Edit Aircraft Effectivity” link at the bottom of the page, to edit the aircraft effectivity details for the FCD.
Select the “Edit Part Effectivity” link at the bottom of the page, to edit the part effectivity details of the FCD.
Select the “Edit Task Information” link at the bottom of the page, to edit the details of the tasks to be performed for FCD execution.
Select the “Edit Parts Requirements” link at the bottom of the page, to edit the details of the piece part required for FCD execution.
Select the “Edit Resource Requirements” link at the bottom of the page, to edit the details of the resources required for FCD execution.
Select the “Edit References” link at the bottom of the page, to edit the reference documents that are needed for executing the FCD.
Select the “Edit Schedules Information” link at the bottom of the page, to edit the periodicity details for the FCD.
Select the “Edit Notes” link at the bottom of the page, to enter the additional notes for the FCD.
Select the “Prepare Aircraft Mod Plan” link to enter the aircraft schedule details in aircraft modification plan.
Select the “Prepare Component Mod Plan” link to enter the component schedule details in component modification plan.
Select the “View Authorization Status Log” link at the bottom of the page, to view the authorization status log details.
Select the “View MCM Details” link at the bottom of the page, to view the modification committee meeting details.
Select the “View MCR Details” link at the bottom of the page, to view maintenance change request details.
This page allows you to edit the details of the selected FCD. FCDs that are in “Fresh” status can be modified. You can edit the category, user status, description and the ATA chapter on which the engineering change has to be performed.
You can modify whether the FCD is applicable for the aircraft, component or engine, priority, background details and reasons. The execution details of the FCD such as the work center, in which the FCD has to be performed, estimated time and man-hours required for the execution of the FCD, can also be modified.
You can also indicate whether,
the FCD has to be performed in the original place of the part,
follow-up action is required after executing the FCD.
You can cancel the FCD in this page. You can enter comments while canceling FCD.
The system performs the following, when the details are modified:
Updates the FCD details and stores the name of the currently logged in user and the server date.
Sets the “Authorization Status” of FCD as “Pending”, if any approval requirements are specified in the “Set Authorization Rules” activity, for the combination of the change document type and the source document type of the FCD. If approval requirements are not specified, the “Authorization Status” is set as “Authorization Not Required”.
If the login employee exists in the authorization hierarchy defined for the combination of the change document type and source document type of the FCD, the FCD must be re-authorized, by all the members of the authorization committee in which the employee exists, and also by the higher level authorization committee.
If the login employee does not exist in the authorization hierarchy, the FCD has to be re-authorized by all the authorization committees (as identified in the “Set Authorization Rules” activity for the combination of the Change Doc Type and Source Doc Type of the FCD).
You can edit the applicability of FCD, ie. Whether it is applicable for aircraft, engine or component only when the effectivity details have not been already specified for the FCD.
In the “FCD Details” group box,
Set the “Applicability” field to “Aircraft”, if the FCD must be executed on aircraft.
Set the “Applicability” field to “Engine”, if the FCD must be executed on engine.
Set the “Applicability” field to “Component”, if the FCD must be executed on component.
You can specify the following details based on which FCD execution will take place:
Check the "On - Wing" box in the “FCD Execution Details” group box, if you wish to perform the engineering change when the part is fitted to the aircraft.
Check the “Follow-Up Action Reqd.” box in the “FCD Execution Details” group box, to indicate that follow-up action is required after executing the FCD.